Saturday, January 1, 2011

Artificial Eye Manufacturers & Suppliers

Artificial Eye Manufacturers & Suppliers

This directory contains listings of qualified manufacturers and suppliers dealing in Artificial Eye. Buyers can contact these Artificial Eye manufacturers, suppliers and exporters by visiting their catalog or by sending request for information.

Chona Surgical Co., New Delhi
Engaged in manufacturing and supplying of phaco practice Artificial Eyes, laser practice Artificial Eye, indirect ophthalmoscopy retinoscopy model Eye and indirect ophthalmoscopy retinoscopy Artificial Eye.

Location:
No. 155- 156, Aggarwal Chamber- 3, Vikas Marg, Shakarpur,
New Delhi,
Delhi, India, 110 092.


United Optical Co., Delhi
Engaged in manufacturing and supplying Artificial Eyes and spherical Artificial Eyes. Artificial Eyes are available in universal size of 22mm, 24mm, 26mm and 28mm.

Location:
No. 5974, 1st Floor, Ballimaran, Chandni Chowk,
Delhi,
Delhi, India, 110 006.


Segal Optics (Segal Instruments Exports), Mumbai
Engaged in exporting Artificial Eye, Artificial right Eye, Artificial left Eye and Artificial human Eye available in a box containing minimum 50 pieces. Also supplies ophthalmic equipment, ophthalmic surgical equipment and telescope.

Location:
368, Kalbadevi Road, Princess Street,
Mumbai,
Maharashtra, India, 400 001.


Medicure Instruments, Delhi, New Delhi
Manufacturers and exporters of Artificial Eye, castroveijo Artificial Eye and sphericals Artificial Eye available in variable sizes. Also deals in selling of Eye microscope, ent microscope and high resolution microscope.

Location:
306, Aggarwal Chamber - IV, 27 Veer Savarkar Block Shakarpur, Vikas Marg,
New Delhi,
Delhi, India, 110 092.


Segal Optics (Mumbai), Mumbai
Exporter and supplier of Artificial Eye, ophthalmic instruments, ophthalmic surgical instruments such as slit lamp, slit lamp microscope, lens meter, keratometer, aperture trial case lens, applanation tonometer and ophthalmic chair unit.

Location:
No. 368, Kalbadevi Road, Marine Lines East,
Mumbai,
Maharashtra, India, 400 002.


Speedway Surgical Co., Delhi, Delhi
Engaged in manufacturing, supplying and exporting of Artificial Eyes that includes opthalmic Artificial Eyes, surgical Artificial Eyes and medical Artificial Eyes.

Location:
1586/31, M. J. Building, Bhagirath Palace,
Delhi,
Delhi, India, 110 006.


Bharat Surgical impex, Gurgaon
Supply and manufacture Artificial Eyes and opthalmic Artificial Eyes. also dealing in opthalmic Artificial Eyes like empty Eye drop botels, surgical sutures, intraoccular lenses and retinal implants.

Location:
No. 129/2, Madan Puri, Main Road,
Gurgaon,
Haryana, India, 122 001.


Eye Care Products (DELHI), New Delhi
Deals in exporting, manufacturing and supplying a wide range of Artificial Eyes. Also offering other Eye care products like mirror gonioscopes and laser lenses.

Location:
987/1 2nd Floor, Shivaji Street, Hardhyan Singh Road Karol Bagh,
New Delhi,
Delhi, India, 110 005.


Komal Optice & Contact Lens Clinic, Mumbai
Contact Lenses,Lowvision Glasses,Reading Glasses,Sunglasses

Location:
70/6, Jawahar Nagar Goregaon West,
Mumbai,
Maharashtra, India, 400 062.


Pisto India Distributors, New Delhi
Designer Artificial Jewellery,Mascaara

Location:
Building No. 267, Block 1, Subhash Nagar,
New Delhi,
Delhi, India, 110 027.


Perfect Eye Care Centre & Eye Clinic, New Delhi
Artificial Eyes,Contact Lenses,Goggles,Intra-ocular Lenses,Lens Frames,Spectacles

Location:
West Zone - 44/2 A, Krishna Puri, Outer Ring Road, Vikas Puri Extention,
New Delhi,
Delhi, India, 110 018.


A-One Artificial Eyes Manufacturers, Bijnor
Artificial Eyes,Human Artificial Eyes,Prosthetic Eyes,Stock Eyes

Location:
1st Floor, Shambha Bazar,
Bijnor,
Uttar Pradesh, India, 246701.


S. M. R. Ophthalmic Private Limited, Mumbai
Foldable Lenses,Intraocular Lenses,Ores,Pmma Lenses

Location:
209, Linkway Estate, Link Road,
Mumbai,
Maharashtra, India, 400 064.


A One Artificial Eyes Company, Bijnor
Artificial Eyes,Human AArtificial Eyes,Implants,Iris,White Conforners

Location:
1st Floor, Shambha Bazar,
Bijnor,
Uttar Pradesh, India, 246 701.


A-One Eyes Co., Bijnor
Artificial Eyes,Prosthetic Eyes

Location:
1st Floor Shambha Bazar,
Bijnor,
Uttar Pradesh, India, 246 701.


R.L. Hansraj & Co, Ahmedabad
Artificial Eye Appliances,Corneal Forcep Eye Instruments,Magnifiers Eye Appliances,Needle Holder Eye Instruments,Scissor Eye Instruments

Location:
2, Jay Vijay Estate, Nr.Keval Kanta Road, Rakhial,
Ahmedabad,
Gujarat, India, 380 023.


Visionex, Chennai
Artificial Intraocular Lenses,Colour Lenses,Contact Lenses,Intraocular Lenses,UV Filter Soft Lenses

Location:
New No. 45, Old No. 23, Mahadevan Street, West Mambalam,
Chennai,
Tamil Nadu, India, 600 033.


Art Eyes A Custom Made Artificial Eye Centre, New Delhi
Disfigured Eye Treatment Services,Rehabilitation Services,Surgery Services

Location:
No. 106, DDA Building 2, Above Mc Donald, Dictrict Centre, Janakpuri,
New Delhi,
Delhi, India, 110 058.


Jindal Medical And Scientific Instruments Company (Pvt.) Ltd., New Delhi
Anaesthesia Equipment,Binocular Microscope,Blood Pressure Monitors,Clinical Thermometer,Diagnostic Equipment,Digital Clinical Thermometer,ENT Equipment,Endoscopy Instruments,Forceps,Hospital Furniture,Hospital Instruments,Hospital Supplies,Laboratory Equipments,Laboratory Glass Wares,Laboratory Plastic Wares,Mediacl Instruemnts,Medical Diagnostic Equipment,Medical Disposables,Medical Forceps,Ophthalmic Equipment,Ophthalmic Intrument,Pathological Microscope,Student Microscope,SurgicaForceps,Surgical Disposable,Surgical Forcep,Surgical Instrument,Surgical Instruments,Surgical Needles

Location:
No. C-53A, Mansarovar Garden,
New Delhi,
Delhi, India, 110015.

Wednesday, December 15, 2010

ocularist india: ocularist india



ocularist india: ocularist india: "RAJU KUMAR BSC in optometry from kolkata fellow LV prasad eye institute hyderabad optometrist/ocularist lvpei hyderabad email- rkumaropto@g..."

Monday, December 13, 2010

Notable people with glass eye

* Baz Bastien – ice hockey player, coach (right eye)
* Sammy Davis, Jr. – singer (left eye)
* Frank Elstner – TV Host (left eye)
* Peter Falk – actor (right eye)
* Nick Griffin – BNP Member of European Parliament and leader (left eye)
* Leo McKern – actor (left eye)
* Claus Schenk Graf von Stauffenberg – German career Army officer and resistance leader (left eye)
* Robert Thurman – writer (left eye)
* Mo Udall – politician
* Carl Ouellet – Canadian Professional Wrestler
* New Jack – American Professional Wrestler (right eye)

[edit]

Implant movement

Implant and prosthesis movement are important aspects of the overall cosmetic appearance after enucleation and are essential to the ideal objective of crafting a lifelike eye similar in all aspects to the normal fellow eye.[4][18] There are several theories of improved eye movement, such as using integrating prosthetic material, pegging the implant, covering the implant (e.g. with scleral tissue), or suturing the eye muscles directly to the prosthetic implant. The efficiency of transmitting movement from the implant to the prosthesis determines the degree of prosthetic motility. Movement is transmitted from traditional nonporous spherical implants through the surface tension at the conjunctival–prosthetic interface and movement of the fornices. Quasi-integrated implants have irregularly shaped surfaces that create an indirect coupling mechanism between the implant and prosthesis that imparts greater movement to the prosthesis. Directly integrating the implant to the prosthesis through an externalized coupling mechanism would be expected to improve motility further.[7]

Despite the reasoning stating that hydroxyapatite orbital implants without a motility peg would yield a superior artificial eye motility,[19] when similar surgical techniques are used unpegged porous (hydroxyapatite) enucleation implants and donor sclera-covered nonporous (acrylic) spherical enucleation implants yield comparable artificial eye motility.[5][7] In two studies[5][20] there were no differences in maximum amplitude between hydroxyapatite and acrylic or silicone spherical enucleation implants,[5] thus indicating that the implant material itself may not have a bearing on implant movement as long as the muscles are attached directly or indirectly to the implant and the implant is not pegged.[4] The motility of a nonintegrated artificial eye may be caused by at least two forces. (1) The rubbing force between the posterior surface of the artificial eye and the conjunctiva that covers the implant may cause the artificial eye to move. Because this force is likely to be approximately equal in all directions, it would cause comparable horizontal and vertical artificial eye amplitudes. (2) An artificial eye usually fits snugly in the conjunctival space (possibly not in the superior fornix). Therefore, any movement of the conjunctival fornices will cause a similar movement of the artificial eye, whereas lack of movement of the fornices will restrict its motility.[5] Imbrication of the rectus muscles over a nonintegrated implant traditionally was thought to impart movement to the implant and prosthesis. Like a ball-and-socket joint, when the implant moves, the prosthesis moves. However, because the so-called ball and socket are separated by layers of Tenon’s capsule, imbricated muscles, and conjunctiva, the mechanical efficiency of transmission of movement from the implant to the prosthesis is suboptimal. Moreover, the concern is that imbrication of the recti over nonintegrated implants actually can result in implant migration.[21] The recent myoconjuctival technique of enucleation is an alternative to muscle imbrication.[4][22][20]

Although it is generally accepted that integrating the prosthesis to a porous implant with peg insertion enhances prosthetic movement, there is little available evidence in the literature that documents the degree of improvement.[7] And although the porous implants have been reported to offer improved implant movement,[23] these clearly are more expensive and intrusive, requiring wrapping, and subsequent imaging to determine vascularization and pegging to provide for better transmission of implant movement to the prosthesis, and also are prone to implant exposure.[4]

Age and size of the implant may also effect the motility, since in a study comparing patients with hydroxyapatite implants and patients with nonporous implants, the implant movement appeared to decrease with age in both groups. This study also demonstrated improved movement of larger implants irrespective of material.[7]

Surgical procedure

Essentially the surgery follows these steps:[7]

* Anesthesia
* Conjunctival peritomy
* Separation of the anterior Tenon’s fascia from the sclera
* Pass sutures through rectus muscles
* Rectus muscles disinserted from the globe
* Rotate and elevate the globe
* Open Tenon’s capsule to visualize optic nerve
* Cauterize necessary blood vessels
* Divide the nerve
* Remove the eye
* Hemostasis is achieved with either cautery or digital pressure.
* Insert orbital implant.
* If necessary (hydroxyapatite) cover the implant with wrapping material before
* Attach the muscle (if possible) either directly (PP) or indirectly (HA) to implant.
* Create fenerations in wrapping material if necessary
* For HA implants drill 1 mm holes as muscle insertion site
* Draw Tenon’s fascia over implant
* Close Tenon’s facia in one or two layers
* Suture conjunctiva
* Insert temporary ocular conformer until prosthesis is received (4–8 weeks later)
* After implant vascularization an optional secondary procedure can be done to place a couple peg or post.

Also under anesthesia

* Create conjunctival incision at the peg insertion site
* Create hole into implant to insert peg or post
* Modify prosthesis to receive peg/post.

The surgery is done under general anesthesia with the addition of extra subconjunctival and/or retrobulbar anesthetics injected locally in some cases. The following is a description of the surgical procedure performed by Custer et al.:[7]

The conjunctival peritomy is performed at the corneal limbus, preserving as much healthy tissue as possible. Anterior Tenon’s fascia is separated from the sclera. Blunt dissection in the four quadrants between the rectus muscles separates deep Tenon’s fascia.

Sutures may be passed through the rectus muscles before their disinsertion from the globe. Some surgeons also suture one or both oblique muscles. Traction sutures or clamps may be applied to the horizontal rectus muscle insertions to assist in rotating and elevating the globe during the ensuing dissection. Tenon’s capsule may be opened posteriorly to allow visualization of the optic nerve. The vortex veins and posterior ciliary vessels may be cauterized before dividing the nerve and removing the eye. Alternatively, the optic nerve may be localized with a clamp before transection. Hemostasis is achieved with either cautery or digital pressure.

The orbital implant is inserted at the time of enucleation. An appropriately sized implant should replace the volume of the globe and leave sufficient room for the ocular prosthesis. Enucleation implants are available in a variety of sizes that may be determined by using sizing implants or calculated by measuring globe volume or axial length of the contralateral eye.

In the past, spherical nonporous implants were placed in the intraconal space and the extraocular muscles were either left unattached or were tied over the implant. Wrapping these implants allows attachment of the muscles to the covering material, a technique that seems to improve implant movement and reduce the incidence of implant migration. Porous implants may be saturated with antibiotic solution before insertion. Because the brittle nature of hydroxyapatite prevents direct suturing of the muscles to the implant, these implants are usually covered with some form of wrapping material. The muscles are attached to the implant in a technique similar to that used for spherical non-porous implants. The muscles may be directly sutured to porous polyethylene implants either by passing the suture through the implant material or by using an implant with fabricated suture tunnels. Some surgeons also wrap porous polyethylene implants either to facilitate muscle attachment or to reduce the risk of implant exposure. A variety of wrapping materials have been used to cover porous implants, including polyglactin or polyglycolic acid mesh, heterologous tissue (bovine pericardium), homologous donor tissue (sclera, dermis), and autogenous tissue (fascia lata, temporalis fascia, posterior auricular muscle, rectus abdominis sheath). Fenestrations in the wrapping material are created at the insertion sites of the extraocular muscles, allowing the attached muscles to be in contact with the implant and improving implant vascularization. Drilling 1-mm holes into the implant at the muscle insertion sites is performed to facilitate vascularization of hydroxyapatite implants. Tenon’s fascia is drawn over the implant and closed in one or two layers. The conjunctiva is then sutured. A temporary ocular conformer is inserted at the completion of the pro- cedure and is worn until the patient receives a prosthesis 4 to 8 weeks after surgery. An elective secondary procedure is required to place the coupling peg or post in those patients who desire improved prosthetic motility. That procedure is usually delayed for at least 6 months after enucleation to allow time for implant vascularization. Technetium bone or gadolinium-enhanced magnetic resonance imaging scans are not now universally used, but they have been used to confirm vascularization before peg insertion. Under local anesthesia, a conjunctival incision is created at the peg insertion site. A hole is created into the porous implant to allow insertion of the peg or post. The prosthesis is then modified to receive the peg or post. Some surgeons have preplaced coupling posts in porous polyethylene implants at the time of enucleation. The post may spontaneously expose or is externalized in a later procedure via a conjunctival incision.